Alarm reset Always reset an alarm after ensuring safety by removing the cause of the alarm and turning the operation signal OFF. [How to reset the alarm]  Turn the ALARM-RESET input to ON and then OFF. (The alarm will be reset at the OFF edge of the input.)  Perform an alarm reset with the monitor mode.  Turn off the power, wait for at least 1 minute, and then cycle the power. When an alarm is reset, “AL00” is displayed for two seconds, then “0” * is displayed. (Except for cycling the power) * The screen selected in the “panel initial view” parameter is displayed.  If the motor does not operate properly after the power is cycled, internal circuit damage is suspected. Please contact ADL .  Continuing the operation without removing the cause of the problem may cause malfunction of the equipment.

Reset using the ALARM-RESET input

Turn the operation signal OFF and then turn ALARM-RESET input ON (keep it ON for 10msec or more). The ALARM-RESET input is disabled while the operation signal is being on. The figure shows an example for which the operation signed is the FWD input.

page 70