STEL Range Agitated Pressure Pots User Guide

Reset with the monitor mode

Set the operation switch to the “STAND-BY” side from the “RUN” side, and reset the alarm by the following steps.

* The screen selected in the “panel initial view” parameter is displayed.

When the present alarm is the prevention of operation at power-on alarm “AL 46” When operating the motor using the front panel, change the setting of the operation switch from the RUN side to the STAND-BY side. When operating the motor using external input signals, the alarm will be reset by turning the operation signal OFF. This is the factory setting. The method to reset the alarm can be changed Refer to page 31 to page 33 for details.

Alarm records

Up to 9 generated alarms are saved in the non-volatile memory in order of the latest to oldest. When clearing the alarm records, perform the alarm record clear on the monitor mode.

 Do not turn off the driver power while an alarm records are being cleared (=while the display is blinking). Doing so may damage the data.

Warnings

The warning types and records can be displayed on the monitor mode. When a warning generates, the WNG output will be turned ON. The WNG output is not assigned to the output terminal at the time of shipment. Refer to page 36 “Description of I/O signals”.