10. TROUBLESHOOTING

LCD is displaying “Please Reset”

1 – the emergency switch has been engaged.  Check emergency switch and if engaged release to working condition.

2 – the communication cable is not connected fully.  Check communication cable is correctly fitted and tightened.

3 – the “Stop” button on the teaching pendent has been pressed.  Press “ORG” to reset the robot’s positioning.

4 – the teaching pendent has developed a fault.  Contact Techcon Systems.

Displaying unusual message after power up

1 – The hardware version is not correct.  Check the version of teaching pendant and PCB.

2 – The teaching pendant cables may have become loose or damaged.  If the teaching pendant cannot communicate normally, or the display is a little dark, disconnect the power supply and then disconnect and reconnect the teaching pendant. DO NOT DISCONNECT THE TECHING PENDANTWHILST THE POWER IS ON.