TS5540-MS Spray Valve User Guide
TYPICAL SETUP
Flow Control Adjustment
Air Cylinder
Needle & Piston
Actuating Air Input
Atomization Port
Fluid Inlet
Body
Needle Seat
Luer Taper
Luer Cap
SPECIFICATIONS & PART NUMBERS
Dimensions are in inches [mm]
TS5540-MS
Part Number:
Size (Imperial):
4.7'' Length x 1.12'' 119.4mm x 28.4mm
Size (Metric):
.
Weight:
0.73 lb (331g)
Fluid Inlet Port:
⅛'' NPT female
Fluid Outlet Port
Spray cap
Aux Air Inlet Port:
10-32 UNF female 70 psi (4.8bar) Min.
Activation Pressure: Max Fluid Pressure: Operating Frequency:
100 psi (6.9bar)
400+ cycles/min.
Mounting Port:
¼-20 UNC-2B female
Viscosity Range:
1 - 5 000cps
303 SS, Teflon®,
Wetted Parts:
ACCESSORIES
Adhesive Dispensing Ltd 55 Alston Drive Bradwell Abbey Ind Estate Milton Keynes Bucks, MK13 9HB, UK Tel: +44 1908 686660 Fax: 01908 686836 info@adhesivedispensing.co.uk www.adhesivedispensing.co.uk
Flui d reservoirs: The valve can be fed from the TS1254 , TS2220, TS2250 or TS1258 Pressure Tank, or from any size syringe barrel or ca rtridge. Dispensing Tips: Precision TT Series dispensing tips, from 14 - 27 gauge, are recommended for this valve type. For the complete dispensing tip offering please visit www.adhesivedispensing.co.uk
Teflon® is a registered trademark of E.I. DuPont. Version 2.00