Cable type for driver supplied with 1, 2 and 5L tank Be sure to ground using the Protective Earth Terminal of the driver.
Two Protective Earth Terminals
are provided on
the driver. Ground either of the two Protective Earth Terminals near the driver. The terminal that is not grounded is used as a service terminal. Use the service terminal according to your specific need, such as connecting it to the motor in order to ground the motor. Do not share the Protective Earth Terminal with a welder or any other power equipment.
f. Connecting to Protective Earth Terminal
To connect to the Protective Earth Terminal, ground using the following grounding terminal. Ground as a short distance as possible.
Ground Terminal
Applicable crimp terminal: Round crimp terminal with insulation cover
Thread size of terminal: M4 Tightening torque: 1.2Nm Applicable lead wire: AWG18 to 14
Static electricity may cause the driver to malfunction or suffer damages.
Be sure to ground the motor and the driver to prevent from being damaged by static electricity.
page 52