STEL Range Agitated Pressure Pots User Guide

p. Setting using the acceleration/deceleration time potentiometer (factory setting)

Setting range: 0.1 to 15.0 sec (factory setting: 0.1 sec)

 Acceleration time

The acceleration time The acceleration time is set as time needed for the motor to reach the rated rotation speed (3000rpm) from the standstill state.

 Deceleration time The deceleration time is set as the time needed for the motor to stop from the rated rotation speed (3000rpm). q. Setting to the operation data with digital setting When setting by the acceleration time and deceleration time of the data mode, set the “analogue acceleration/deceleration time” parameter of the parameter mode to the digital setting, \set the time needed to reach the set rotation speed.

page 37

Setting range: 0.1 to 15.0 sec (factory setting 0.5 sec)

r. Motor operation If the acceleration time and deceleration time are set shorter than 0.5 seconds, the motor takes for a longer time than 0.5 seconds to reach the speed. If they are set to approximately 0.5 seconds or more, the motor can accelerate and decelerate in the setting time. (With no load) When the frictional load or load inertia is increased, the operating time to reach the setting will be longer.

page 41

Made with FlippingBook Online newsletter creator