STEL Range Agitated Pressure Pots User Guide
Setting range: Off: Operation/standstill using front panel (Factory setting) On: Operation/standstill using external signals (The operation with the front panel is Enabled) rE: Operation/standstill using external signals (The operation with the front panel is Disabled.)
The “external operation signal input” parameter (ioEn) is found in the parameter mode page 32).
Front panel operation: Operation using the switches and setting dial on the front panel can be set to “Enable: O” or “Disable: x”.
When the setting is “ON” Operation by switches on the front panel: Enable
When turning the operation input signal ON, while the operation swtich is Set to the RUN side, the motor rotates.
When the operation switch is set to the “STAND-BY” side, the motor decelerates to a stop even if the operation input signal is being ON. Turning the setting dial changes the motor rotation speed. If the rotation direction switch is changes, the motor rotates in the opposite direction.
When the setting is “RE” Operation by switches on the front panel: Disable
If the operation switch or rotation direction switch are operated while setting to “RE”, “rE”, will be displayed.
Also, if the setting dial is operated while displaying the rotation speed, alarm, or warning in the motor mode, “rE” will be displayed.
The data mode, parameter mode, and the I/O monitor of the monitor mode are enabled (possible to set).
The display time of “rE” varies depending on the switch.
When setting the operation switch to the “RUN” side, “rE” will be displayed continuously. When switching the rotation direction switch to “FWD” (or “REV”), or when operation the setting dial, “rE” will be displayed for two seconds.
page 31
Made with FlippingBook Online newsletter creator