TS6500CIM Automatic Techkit Semkit Mixer User Guide

8.

SETUP AND OPERATION

WARNING: This unit is equipped with a voltage selector switch. Please check to make sure the voltage selector is set to match the voltage input.

8.1 Voltage Selection and Fuse Replacement

1.

Select the proper voltage by sliding the voltage switch up or down

Voltage Range 100V – 120V 220V – 240V

Voltage Setting

Fuse Rating 2 Amp, Type F 2 Amp, Type F

115V 230V

Fuse Replacement: The unit is shipped with the fuse installed. If fuse needs to be replaced please follow instructions below

2. Remove the fuse holder by using a flat head screw driver to pry it open. 3. Insert correct fuse into the fuse box, refer to table above 4. Re-install the fuse holder into the unit

FUSE HOLDER WITH FUSE INSTALLED

VOLTAGE SELECTOR SWITCH

FUSE HOLDER

FUSE HOLDER

FUSE

SCREW DRIVER

Figure 6.0 Fuse Installation