7. TROUBLE SHOOTING PROBLEM
POSSIBLE CAUSE
CORRECTION
Fluid pressure too low
Increase fluid pressure
Operating pressure too low
Increase air pressure to 70 psi (4.8 bars)
No Fluid Flow
Dispense tip clogged
Replaced tip
Fluid cured in valve chamber
Clean valve thoroughly
The stroke adjustment is fully closed
Open stroke adjustment counterclockwise. One full turn max.
Fluid pressure fluctuating
Make sure fluid pressure is constant
Valve operating pressure is too low
Increased valve pressure to 70 psi (4.8 bars) Check to make sure the valve controller is providing a consistent output
Inconsistent Fluid Flow
Valve open time is not consistent
Air trapped in fluid housing
Purge valve
Fluid drools after the valve closes, eventually stopping
Air trapped in fluid housing
Purge valve
Worn diaphragm
Replace diaphragm
Material build up in fluid housing Fluid pressure exceeds 70 psi (4.8 bars) Valve re-assembled incorrectly after cleaning
Clean fluid housing
Steady Drip
Lower fluid pressure
Refer to Maintenance section
Fluid leaks between diaphragm and fluid housing Mounting screws loose
Tighten screws
Fluid leaks out of bleed hole Diaphragm ruptured
Replace diaphragm
7