TS250 TS255 Dispensers User Guide

being sucked back into the unit. Also do not overfill the barrel and to lay the barrel on its side • Do not smoke or use open flame when flammable materials are being dispensed • This equipment is for indoor use only 2 SYMBOL DEFINITIONS Symbol Definition Power On/Off Cycle Mode Timer Vacuum

4

FEATURES

12

10

2

4

13

11

3

16

Pressure

1

5

6

9

15

14

3

SPECIFICATIONS

7

8

152mm X 165mm X 178mm (6” X 6.5” X 7.0”)

Size

Weight

1.2 kg (2.6lbs)

Figure 1.0

Input Voltage Rated Power

24 VDC

Items Description 1 Power Button 2 Mode Button 3

10 W

Air Input

100 psi (6.9 bar) Max.

Pollution Degree

II

Counter Reset Button

Installation Category

I

Display

4 5 6 7 8 9

Indoor Use

Altitude up to 2,000m (6,562ft) 0˚C to 50˚C (32˚F to 122˚F) -10˚C to 60˚C (14˚F to 140˚F)

Air Pressure Gauge Air Pressure Regulator Pulsed Air Outlet Vacuum Control Time Control Knob

Operating Temperature Storage Temperature

80% for temperature up to 31˚C (87.8˚F) Decreasing linearly to 50% relative humility at 40˚C (104˚F)

Max. Relative Humidity

Receiver head air hose holder

10 11 12 13 14 15 16

TS250 = 0-100 psi (0- 6.9 bar) TS255 = 0-15 psi (0-1 bar)

Air Output

Foot Switch Receptacle

Power Receptacle I/O Connection

Vacuum

406mm (16”) of Hg 0.020-60.000 seconds

Timer

Exhaust Port

Cycle Mode

PURGE, TIMED

Air Inlet

Timing Repeat Tolerance

+/- 0.001%

Cord Lock

Cycle Rate

600 cycles/min

LCD

16 X 2 display segments

3

4

Made with FlippingBook - Online Brochure Maker