TS2220 TS2250 TS22100 TS2216 User Guide 26

USE AND MAINTENANCE MANUAL

7.3 Suction tube replacement

This procedure serves when the suction tube inside the tanks must be changed. To do this:

1. Loosen the screw that holds the suction tube in position; 2. Remove the old suction tube; 3. Insert the new tube and take the correct measurement, leaving 5 centimeters of distance between the end of the tube and the tank bottom; 4. Cut the tube at 45°, so that the tube does not stick to the tank; 5. Insert the new tube in its position and tighten the screw, so that the suction tube remains in position.. ATTENTION! The tube must not be tightened too much otherwise there is a risk of breaking it or choking it too much, affecting the dosing quality.

ADHESIVE DISPENSING LTD

COD.: DTVI_PT_2447 REV.: 02 DATE: 10/02/2026

EN

Any reproduction (total or partial) of this document noaut thorizedby the manufacturer will be punished according to the law.