TS1212 Pinch Tube Valve User Guide
7. TROUBLE SHOOTING PROBLEM
8. PINCH TUBE REPLACEMENT CAUTION: Make sure the fluid pressure is released before disassemble the valve. Refer to figure 5.0
POSSIBLE CAUSE
CORRECTION
Fluid pressure too low
Increase fluid pressure
1. Release fluid pressure. 2. Disconnect fluid line. 3. Disconnect valve air line.
Operating pressure too low Dispense tip clogged or damaged Fluid cured in pinch tube The stroke adjustment closed
Increase air pressure to 50 psi (3.4 bars)
Replaced tip
4. Remove the valve cap (1), the spring (6) and the shut off piston (5) 5. Lift the two ends of the tube (2) out of the grooves of the valve body (3). 6. Hold the pinch tube at the female luer lock fitting and pull it out of the valve body. 7. Dispose the used pinch tube in an appropriate waste container. 8. Install a new pinch tube by inserting the male fitting of the tube through the valve body. 9. Snapped the both ends of the pinch tube into the groove of the valve body. 10. Reinstall the shut off piston, the spring and the flange.
No Fluid Flow
Replace with new tube
Open stroke adjustment counterclockwise Make sure fluid pressure is constant Increased valve pressure to 50 psi (3.4 bars) Check to make sure the valve controller is providing a consistent output
Fluid pressure fluctuating
Valve operating pressure is too low
Inconsistent Fluid Flow
Valve open time is not consistent
Air trapped in fluid line Purge valve
5
6
Pinch tube lose its flexibility
Replace with new tube
Decrease in fluid flow
Air trapped in fluid line
Purge valve
Fluid drools after the valve closes, eventually stopping
Pinch tube is not installed properly
Re-install tube, follow instructions
Steady drip
4
1
3
2
Figure 5.0
7
8