STEL Range Agitated Pressure Pots User Guide

Trouble:

The rotation speed is not displayed

Possible Cause

Solution

The “panel initial view” Parameter is not set to The rotation speed.

Set the “panel initial view” parameter to

the rotation speed.

Trouble:

The motor rotates in the opposite direction then the one specified

Possible Cause

Solution

The FWD input and REV Check the connection of the FWD input input are connected and REV input.

wrongly otherwise not connected correctly.

The gear ratio that the gearhead output shaft rotates in the opposite direction against the motor rotation direction is used.

Check the operating manual supplied with the motor for the rotation direction of the

gearhead output shaft.

The rotation direction Switch is set wrong.

Check the rotation direction switch.

When the rotation

Check the setting of the “external operation

Direction switch is set To REV, the “external operation signal input” parameter is set to ”RE”

signal input” parameter.

Trouble:

The setting cannot be performed using the setting dial

Possible Cause

Solution

The lock function has

Release the function.

been enabled.

Trouble:

The set rotation speed is not saved.

Possible Cause

Solution

It is not determined

After setting the rotation speed, determine

by pressing the

it by pressing the setting dial.

setting dial.