STEL Range Agitated Pressure Pots User Guide
Pressure Relief Procedure To reduce the risk of body injury, including fluid splashing into the eyes, NEVER attempt to open the reservoir without first performing this procedure.
1. Turn pressure to 0 on the reservoir air regulator.
2. Actuate the air relief valve. Hold the relief valve open until any hissing sounds end.
3. Confirm that the indicated gauge pressure is zero. If the gauge reads zero, slowly release the cover clamps and remove the cover.
4. If the pressure gauge does not read zero after performing Steps 1 and 2, remove the air input hose from the air regulator and set the regulator pressure to zero. A hissing sound should be heard from the regulator during this step. Once the gauge reads zero, return to Step 3. Do not use the reservoir until the air relief valve is replaced.
Refilling To open the tank, follow the Pressure Relief Procedure above. Follow setup steps 1-8 to refill, make sure the air pressure is off or disconnected from the air motor.
Note: When pressurised, it is normal to hear a hissing sound coming from the regulator. This is due to the constant-bleed regulator feature.
Wetted Parts List
The following materials come in contact with the fluid during normal use:
1. Polyethylene (fluid feed tubing)
2. For all ST models: Stainless steel grade 303/304 (reservoir body and lid)
3. For all STEL models stainless steel grade 303/304 (mixing shaft and blade)
4. Optional polyethylene jar
If you have any questions, please contact us for assistance. ------------------------------------------------ info@adhesivedispensers.co.uk
page 62