STAG Pressure Pots User Guide
Trouble:
Air leak from agitator
Possible Cause
Solution
Air motor not sealed
Check sealing motor O-ring. If leak continues after changing O-ring, replace motor.
properly
Trouble:
Bad quality mix or no agitation
Possible Cause
Solution
Slipping shaft, shaft coupling or
Make sure the shaft, shaft coupling and mixing blade a tightened properly.
mixing blade
Low air pressure or no air supply
Check factory air pressure. Check
for any signs of leak in the tubing and fittings connected to the air motor. Check for signs of pollution in the air line, filter and motor.
High viscosity fluid
Check compatibility between equipment and fluid viscosity.
Trouble:
Vibration during operation
Possible Cause
Solution
High viscosity fluid
Check compatibility between equipment and fluid viscosity.
Bent shaft
Check shaft alignment. Replace shaft.
Loose coupling
Check shaft coupling tightness.
Faulty bearing
Replace air motor.
Trouble:
Overheating motor
Possible Cause
Solution
Motor is overloaded
Check compatibility between equipment and fluid viscosity. Upgrade air motor or change mixing blade design.
page 30
Made with FlippingBook flipbook maker