ADL100 Timed Adhesive Dispenser User Guide 2025
ADL100 Timed Adhesive Dispenser User Guide 2025
Precision Fluid Dispenser ADL100 USER GUIDE
Sales and service www.adhesivedispensers.co.uk info@adhesivedispensers.co.uk Tel. +44 (0) 1908 686660 Fax. +44 (0) 1908 686836
www.adhesivedispensing.co.uk sales@adhesivedispensing.co.uk +44 (0) 1908 686660
SPECIFICATION ADL100 USER GUIDE
The ADL100 fluid dispenser provides many years of trouble-free, productive service. This Operating Guide will help you maximize the usefulness of your new dispenser. Please spend a few minutes to become familiar with the controls and features of your new dis penser. Please follow our recommended testing advice. Review the information we have included in the guide based on many years of industrial flu id dispensing experience. Most questions you will have are answered in this guide. However, if you need assistance, please contact us or your authorised distributor.
For support, call us on +44 (0) 1908 686660
Our Promise We pledge that you will be completely satisfied with our range of dispensing products. We strive to ensure that every ADL product is supplied to high quality standards. If you feel that you are not receiving the support you require, or if you have any questions or com ments, please email or call us for an immediate response. Our goal is to provide high performance equipment and components, and to build long-term custom er relationships based on excellent quality, service, value and trust.
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
CONTENTS ADL100 USER GUIDE
Initial Steps One : Unpack and use the checklist enclosed with the Dispenser Kit to identify all items. If there is any discrepancy, please call us immediately. Two : Power and compressed air should be available where the dispenser is to be set up. Air pressure should be be tween 80 and 100 psi (5.5 and 6.9 bar). If you are not using an ADL five micron filter regulator #TSD800-6, be certain your factory air is properly filtered and dry and a regulated, constant air pressure is supplied to the dispenser. Warning: Bottled nitrogen can be used. If high pressure bottled air or nitrogen is used, a high pressure regulator must be installed on the bottle and set at 100 psi maximum. The TSD800-6 filter regulator is not recommended. Three : ACTIVATE your One Year Limited Warranty. Please fill in and return the Warranty card. Or if you prefer, call the appropriate number listed below, provide the serial number on the back of your dispenser and respond to a few short questions.
If required, please call our support team on +44 (0) 1908 686660
Connection ..................................... Setup for Testing ............................ Testing the Dispensers .................... Making Timed Deposits of Medium to Thick Fluids Changing Deposit Size and Drawing Stripes Programmable Timer ......................... How to Use the Vacuum Control ... Making Timed Deposits of Watery-thin Fluids Component Dispensing System...... Loading the Barrel Reservoirs........ Schematic & Parts............................ Troubleshooting .............................. Suggestions & Reminders................. Reordering Components .................. Two Year Limited Warranty..............
4-5 6-7 8-9
9
10-11
12-13 14-15
16 17 18 19 20
Meets applicable CE requirements.
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
SETUP ADL100 USER GUIDE
Power cord
Foot pedal assembly
Air input hose
Mains air, 100 psi max
Check voltage label on dispenser
Adapter assembly
Push in the tube to the quick connect fitting
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
SETUP ADL100 USER GUIDE
Connection 1. Connect the air input hose to a plant air source. Set mains air supply within 80 to 100 psi (5.5 to 6.9 bar). Where required, use an ADL five-micron filter regulator #TSD800-6. 2. Push the air input hose in to the dispenser. Standard 6mm OD hose push fit. 3. Push in the foot pedal connector, tighten the threaded collar. 4. Refer to “Making Timed Deposits of Watery-thin Fluids” on page 10 if applicable. 5. Attach the 30cc barrel (#930-N) to the 30cc adapter head (# 73003RHB).
6. Take the 30cc barrel adapter assembly (#73003RHB on the adapter head) and insert the 6mm OD adapter tube and push into the air output fitting on the front panel quick push connect. Place the barrel in the barrel stand. 7. During this initial testing, you will not use the vacuum control. Keep this control shut off (turned completely clockwise—do not force).
For support, email us at orders@adhesivedispensing.com
www.adhesivedispensing.co.uk sales@adhesivedispensing.co.uk +44 (0) 1908 686660
FUNCTIONS ADL100 USER GUIDE
Controls and Connections
www.adhesivedispensing.co.uk sales@adhesivedispensing.co.uk +44 (0) 1908 686660
FUNCTIONS ADL100 USER GUIDE
Setup for Testing Power switch 1 should be off.
The amount of material dispensed each cycle depends on the combination of air pressure, time of air pulse, viscosi ty of material and dispensing tip size.
Note: For watery liquids and Cyanoacrylates, refer to “Making Timed Deposits of Watery-thin Fluids” on page 10.
The first step is to remove the tip cap from the pre-filled barrel of blue test material (twist and pull). Replace it with an 18 gauge (green) tapered dispensing tip (#TTN18). Press the tip on and twist clockwise to lock.
Pull out air pressure regulator knob 2 until it “clicks” into the unlocked position. Turn clockwise to adjust the air pres sure to 30 psi (2.1 bar) for the initial tests.
Always set the pressure desired by turning the air regulator knob 2 clockwise. To reduce the pressure, turn the knob counter clockwise until the gauge 3 reads a lower pressure than desired. Then increase and stop at desired pres sure. Push knob in to lock. Set time control 4 to #7. Dispense cycle time increases from 0.01 second minimum to 1.0 second as knob is turned clockwise. Be sure vacuum control 5 is turned off (turn clockwise) for initial tests. Press power switch ❶ to turn on the dis penser. It will light green.
Press timer bypass switch 6 . It will light orange. In this operation mode, the timer will be bypassed to fill the dispens ing tip before you begin testing. A continuous flow of material will occur as long as the foot pedal is pressed.
Please continue to page 8 for test procedures.
www.adhesivedispensing.co.uk sales@adhesivedispensing.co.uk +44 (0) 1908 686660
MAKING DEPOSITS ADL100 USER GUIDE
Making Timed Deposits of Medium to Thick Fluids You are now ready to test the dispenser with a thick, non-levelling fluid such as a sealant, paste or grease.
Check your initial settings:
A) Air gauge reads 30 psi. B) Timer is set at number 7.
C) Green tapered tip is on the test barrel. D) Power and timer bypass switches are on.
Holding the barrel as shown, rest the tip on a piece of card or paper. Press the foot pedal until the tip fills and some fluid is pushed out onto the paper. Repeat this whenever you change to a new tip.
With the tip filled, turn off the timer bypass switch (orange light out).
Take the Dot Test sheet supplied and put the tip on a 1/4" circle, holding the barrel as shown. Press the foot pedal. Check the dot size. Make several more similar dots and note the size consistency.
Remember – When the orange timer bypass switch is on, a continuous flow of material will occur as long as the foot pedal is pressed. The orange light must be off to make timed deposits.
Note - always bring the tip into contact with the work surface substrate at the shown angle. After the tip is in position, press the foot pedal. Release the pedal and remove the tip by lifting straight up.
www.adhesivedispensing.co.uk sales@adhesivedispensing.co.uk +44 (0) 1908 686660
MAKING DEPOSITS ADL100 USER GUIDE
Changing Deposit Size, Making Beads The dot size is determined by the tip diameter, the air pressure output set ting and the pulse time. For large dots, use a large tip, higher pressure and more time. Usually, you want to use as short a time pulse as possible. To increase the dot size, slightly increase output air pressure, or increase tip size, or increase both. Dot Test with Green Tapered Tip #TTN18 First, follow the settings illustrated on the right, and you will get dots about the size shown. Try other times and pressures to see how easy it is to get just the dot size you want. Dot Test with Blue Tapered Tip #TTN22 These tests show the effect of using a smaller diameter tip. Replace the green tip with the blue (22 gage) tapered tip. Now, turn on the timer bypass switch and press the foot pedal to fill the tip. Then, turn off the timer bypass switch (yellow light out) and press the foot pedal. To make beads, press the timer bypass switch (yellow light on). With the tip in contact with the test sheet, press and hold down the foot pedal while making a bead or stripe. Programmable Timer Each ADL100 dispenser has a rotary timer with adjustable time ranges. The DIP switch that controls the timer has been set at the factory for a time range of 0.01 to 1.0 second, with the initiation set to MOMENTARY contact. If a longer time range is required, or foot pedal operation needs to be changed from momentary to maintained, choose the appropriate dip switch setting in the chart below.
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
VACUUM SUCK-BACK ADL100 USER GUIDE
How to Use the Vacuum Control Making Timed Deposits of Watery-thin Fluids
The vacuum control allows low viscosity fluids, even water, to be consistently dispensed without dripping between cycles. The vacuum places a negative pressure on the fluid in the barrel and pre vents dripping. For these tests, please use water. 1. While holding the barrel upright in one hand, remove the orange end cap 1 and insert a blue easy - flow piston 2 . Push piston down to fluid level from top as shown. 2. Attach the barrel to the 30cc adapter 3 . Snap the safety clip tightly closed to prevent any dripping or bubbling. Remove the tip cap ❹ and attach the 25 gauge (RED) AD725050PK tip. 3. Set air pressure at 5 psi. 4. Press the timer bypass switch (orange light on). 5. With the barrel pointing downward over a container, unsnap the safety clip. Then press the foot pedal to fill the tip. 6. Set the timer at number 5. Press the timer bypass switch again (orange light out). 7. If a drop begins to form at the end of the tip, slowly turn the vacuum control knob counter clock wise to stop the drop from growing. Wipe the tip and adjust vacuum as necessary. 8. Take the barrel and place the tip on the test sheet. Press the foot pedal and release. Check the dot size. Increase or decrease by adjusting pressure and time.
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
DISPENSING WITHOUT A PISTON ADL100 USER GUIDE
If you choose not to use the piston, please follow these instructions carefully: 1. While holding the barrel upright in one hand, twist on an orange, black or white tip cap. Using a small funnel, fill about 2/3 full with your fluid. 2. Open the white safety clip and attach the barrel to the 10cc adapter. 3. Close the white safety clip as tight as possible. 4. Increase vacuum by gently turning vacuum control knob counter clockwise. 5. Then, without tipping the barrel upside down, remove the tip cap and attach the 25 gauge (red) # AD725050PK tip. 6. Open the safety clip. Your material may begin to bubble. Reduce vacuum by turning vacuum control knob clockwise. 7. If a drop begins to form at the end of the tip, slowly turn the vacuum control knob counter clockwise to stop the drop from growing. Wipe the tip and adjust vacuum as necessary. Now the fluid is in proper balance. It does not bubble or drip.
Some things to remember If you do not use the piston when dispensing thin fluids:
Do not tip the barrel upside down or lay flat. This will cause the liquid to run into the dispenser.
When changing tips or attaching a tip cap, snap the safety clip completely closed to prevent any dripping or bubbling.
Use an ADL filter trap (#1400-FLT). This filter trap will impede the flow should the low viscosity liquid be sucked back towards the dispenser.
Repeat tests as before, keeping the air pressure low and adjusting the time for different deposit sizes.
Contact us if you have any questions.
In the UK, call +44 (0) 1908 686660 .
For support, email us at orders@adhesivedispensing.com
IMPORTANT Regardless of the fluid viscosity, using the correct piston will give you improved results. White PE piston for most fluids, blue Easy Flow piston for watery thin fluids and red flat wall piston for thick, stringy fluids. See pages 12 - 13 for a complete description of how our pistons work and the benefits they can bring to your applications.
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
DISPENSING THICKER FLUIDS ADL100 USER GUIDE
For Thick Fluids
If you dispense thick fluids, several problems may occur. First, the repetitive air cycles can bore tunnels through non levelling fluids, causing spitting and inconsistent deposits. Second, thick fluids contain trapped air that leads to drool ing and oozing. These problems are eliminated by using the PE piston. That's because the white pistons prevent tunnelling by providing a barrier to the pulsed-air cycles, and prevent oozing by responding to the pressure of trapped air with a slight suck-back movement after the dispense cycle. The white PE piston is used for most fluids. However, if you are applying RTV silicone and find that the piston bounces and causes stringing, switch to the red, flat wall piston. The PE pistons make barrel filling easier, too. As you load the fluid in, air is trapped in the bottom and throughout the fluid. Simply insert a PE piston and gently press down on the fluid as far as possible. This action forces out most of the air and results in consistent deposits.
Air Pressure OFF
Air Pressure ON
No drips or ooze
For support, email us at orders@adhesivedispensing.com
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
DISPENSING THINNER FLUIDS ADL100 USER GUIDE
For Thin Fluids
If you use low to medium viscosity fluids, the white PE piston has several advantages.
First, vacuum adjustment is much less sensitive. Second, the piston prevents fumes from the fluid being exhausted into the work environment. Third, the piston prevents fluid backflow into the dispenser if the barrel is inadvertently turned upside down. Fourth, using the piston makes it easy and safe to change tips without dripping.
Note: If you use watery-thin fluids such as solvents, cyanoacrylates and anaerobics, specify the blue colour “Easy Flow” wiper pistons. Available in 3cc, 5cc, 10cc and 30cc/ 55cc sizes.
PE White™ piston prevents fluid backflow
Blue Easy-Flow piston for improved control of very low viscosity fluids.
Fumes cannot escape.
Note: The Easy-Flow piston works OK with an air gap between the barrier and fluid.
No air gap when using the White PE™ piston.
Note: If you choose not to use a piston, please refer to page 11 for instructions.
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
DISPENSING CYANOACRYLATE & SOLVENTS ADL100 USER GUIDE
For Cyanoacrylates and Solvents
Caution: Do not completely fill barrels. The optimum fill is a maximum 2/3 of the barrel capacity If the fluid you are dispensing is pourable, take the barrel, twist on a tip cap and pour your fluid in. If appropriate, in sert the PE piston (see page 13). Carefully press the piston down until it contacts the fluid. The barrel is now ready for use. If you are dispensing solvents, cyanoacrylates or anaerobics, use the Easy-Flow piston. If your fluid is thick or non-levelling, you can spoon it into the barrel with a spatula Or, if the fluid comes packed in a 1/10 gallon cartridge, try loading the barrel with a caulking gun. Then press in the PE piston to move the fluid to the bottom of the barrel and to remove trapped air.
Fill procedure for pourable fluids
Fill procedure for thick fluids (shown: caulk gun)
1/2 maximum fill
2/3 maximum fill
Easy-Flow
Fill procedure for cyanoacrylates or watery-thin fluids
1/2 maximum fill
For support, email us at orders@adhesivedispensing.com
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
BARREL FILLING ADL100 USER GUIDE
We offer productive alternatives to traditional barrel loading methods. Here are a few suggestions that can help keep your work area clean, save time and reduce the chance of entrapped air in the fluid. 1. You could use the ADL #TS900-12- barrel loader. Pack the fluid into the 12 ounce cartridge as shown. Then place the pre-filled cartridge into the barrel loader. Using air pressure, the barrel loader fills the barrel (with piston) from the bottom up. If the fluid comes packed in a 1/10 gallon (310 ml.) caulking type cartridge, use the ADL #900-110 barrel loader. 2. If you receive frozen epoxies or other fluids in medical type syringes with a manual plunger, ask your fluid packager to use ADL industrial grade bar rels, or request our luer-to-luer fitting #TSD931-28 to transfer the material. Please call an ADL Product Specialist for additional application assistance.
Filling the cartridge for the barrel loader.
# TSD931-28 Luer-to-luer fitting
900-120 Syringe Barrel Loader 12oz (Specify # 900-110110 for prefilled 1/10 gallon caulking tubes)
2/3 maximum fill
Barrel Racks # SR03-90W holds (90) 3cc barrels # SR05-60W holds (60) 5cc barrels # SR10-40W holds (40) 10cc barrels # SR30-24W holds (24) 30/55cc barrels
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
TROUBLESHOOTING ADL100 USER GUIDE
NO POWER
Troubleshooting 1. Check voltage at wall outlet. 2. Check fuse. Replace fuse. 3. Unplug from wall, remove top cover, visually inspect for any loose or shorted connections.
POWER, BUT NO LIGHT
Module must be replaced.
POWER, LIGHT, BUT MACHINE DOES NOT OPERATE
1. Unplug power input cord. 2. Check foot pedal connection, foot pedal and internal switch.
1. Check dispensing tip, barrel and material for possible clogging. 2. Check air gauge to be sure air pressure is not varying. 3. Check to see if there are air bubbles in the material being dispensed. 1. Use White PE pistons or Easy-Flow Blue to prevent this. (See pages 12-13.) 2. If it occurs, attach an empty barrel, (put timer bypass switch on), put barrel in a cup and press the pedal to expel the sucked-back fluid. 3. If problem cannot be corrected, contact an ADL Product Specialist for assistance. Dispensers can be returned to ADL for repair.
INCONSISTENT DOTS
MATERIAL SUCK-BACK
1. Check to be sure timer bypass switch is off (orange light out). 2. Check DIP switch positions (see page 9).
TIMER SEEMS INOPERATIVE
Note: The ADL100 timer is very reliable. Most questions about the timer are resolved by simply turning the timer bypass switch off (orange light out).
ALWAYS SWITCH OFF THE DISPENSER WHEN NOT IN USE TO CONSERVE POWER.
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
SUGGESTIONS ADL100 USER GUIDE
Suggestions & Reminders 1. Always use an ADL piston to make your barrel loading, dispensing and handling cleaner, safer and more accurate.
Caution : If you dispense watery-thin fluids and choose not to use white PE pistons – do not increase vacu um pressure rapidly and do not tip the barrel. Vacuum may pull liquid into the air hose; or when tipped, liquid may flow back into the dispenser.
2. Always use new barrels and tips. Carefully dispose of after use. This procedure ensures maximum cleanliness, prevents contamination and provides proper safety.
3. Do not completely fill the barrel. For most fluids, optimum fill is a maximum 2/3 of the barrel capacity. For cy anoacrylates or watery-thin fluids, optimum fill is 1/2 of the barrel capacity.
4. Use the ADL syringe barrel racks to help organize bench space for filled barrels.
5. Depending on the type of work you are doing, it may be easier to bring the work to the barrel. Mount the barrel on a stand such as the ADL # 560021.
6. To ensure smooth fluid flow and to make consistent deposits, always have the tip at about a 45° angle to the work surface.
Barrel Racks
560021 Stand
DISPENSING COMPONENTS ADL100 USER GUIDE
Tapered tips
gauge 31.75mm Long 60mm Long
30° bent AD8TTA-B AD10TTA-B AD11TTA-B AD12TTA-B AD13TTA-B AD14TTA-B AD15TTA-B AD16TTA-B AD18TTA-B AD20TTA-B AD21TTA-B AD22TTA-B AD23TTA-B AD25TTA-B AD27TTA-B
colour Clear Lime Peach Dk. Red Lt. Blue Olive Amber Grey Green
black uv
id
8
AD8TTN-B AD10TTN-B AD11TTN-B AD12TTN-B AD13TTN-B AD14TTN-B AD15TTN-B AD16TTN-B AD18TTN-B AD20TTN-B AD21TTN-B AD22TTN-B AD23TTN AD25TTN-B AD27TTN-B AD30TTN-B AD30TTN-B
n/a n/a n/a n/a n/a
n/a n/a n/a n/a n/a
3.50mm 3.00mm 2.50mm 2.34mm 2.00mm 1.60mm 1.37mm 1.22mm 0.84mm 0.61mm 0.51mm 0.41mm 0.33mm 0.25mm 0.20mm 0.15mm 0.10mm
10 11 12 13 14 15 16 18 20 21 22 23 25 27 30 32
AD14TTL-B AD15TTL-B AD16TTL-B AD18TTL-B AD20TTL-B
TT14-UV
n/a
TT16-UV TT18-UV TT20-UV
Pink
n/a n/a n/a n/a n/a n/a n/a
Purple
n/a
Blue
TT22-UV
Orange
n/a
Red Clear
TT25-UV TT27-UV TT30-UV
n/a n/a
Lavender Yellow
n/a
Precision blunt end tips
gauge 0.25”
0.5”
1.0”
1.5”
2.0”
colour
id
10 AD710025PK AD710050PK AD710100PK AD710150PK AD710200PK Lt. Green 11 AD711025PK AD711050PK AD711100PK AD711150PK AD711200PK Lt. Orange 12 AD712025PK AD712050PK AD712100PK AD712150PK AD712200PK Dk. Blue 13 AD712025PK AD713050PK AD713100PK AD713150PK AD713200PK Dk. Red 14 AD714025PK AD714050PK AD714100PK AD714150PK AD714200PK Olive 15 AD715025PK AD715050PK AD715100PK AD715150PK AD715200PK Amber 16 AD716025PK AD716050PK AD716100PK AD716150PK AD716200PK Grey 17 AD717025PK AD717050PK AD717100PK AD717150PK AD717200PK Lt. Amber 18 AD718025PK AD718050PK AD718100PK AD718150PK AD718200PK Green 19 AD719025PK AD719050PK AD719100PK AD719150PK AD719200PK Brown 20 AD720025PK AD720050PK AD720100PK AD720150PK AD720200PK Pink 21 AD721025PK AD721050PK AD721100PK AD721150PK AD721200PK Purple 22 AD722025PK AD722050PK AD722100PK AD722150PK AD722200PK Blue 23 AD723025PK AD723050PK AD723100PK AD723150PK AD723200PK Orange 25 AD725025PK AD725050PK AD725100PK AD725150PK AD725200PK Red 26 AD726025PK AD726050PK AD726100PK AD726150PK AD726200PK Peach 27 AD727025PK AD727050PK AD727100PK AD727150PK AD727200PK Clear 28 AD728025PK AD728050PK AD728100PK AD728150PK AD728200PK White
3.10mm 2.60mm 2.26mm 1.90mm 1.60mm 1.37mm 1.25mm 1.00mm 0.84mm 0.70mm 0.61mm 0.51mm 0.41mm 0.33mm 0.25mm 0.24mm 0.21mm 0.18mm 0.15mm 0.12mm 0.08mm colour Dk. Blue Dk. Red Olive Amber Grey Lt. Brown
30 32 34
AD730025PK AD7300050PK AD730100PK n/a AD732025PK AD732050PK AD732150PK n/a
n/a n/a n/a
Lavender
n/a
AD732025PK AD734050PK n/a
n/a
Lime
Angled blunt end tips - Inner diameters are as above
gauge 45° 0.5”
45° 1.0”
45° 1.5”
90° 0.5”
90° 1.0”
90° 1.5”
12 13 14 15 16 17 18 19 20 21 22 23 25 26 27 28 30 32 34
AD71205045 AD71305045 AD71405045 AD71505045 AD71605045 AD71705045 AD71805045 AD71905045 AD72005045 AD72105045 AD72205045 AD72305045 AD72505045 AD72605045 AD72705045 AD72805045 AD73005045 AD73205045 AD73205045
n/a n/a
n/a n/a
AD71205090 AD71305045 AD71405090 AD71505090 AD71605090 AD71705090 AD71805090 AD71905090 AD72005090 AD72105090 AD72205090 AD72305090 AD7205090 AD72605090 AD72705090 AD72805090 AD73005090
n/a n/a
n/a n/a
AD71410045 AD71510045 AD71610045 AD71710045 AD71810045 AD71910045 AD72010045 AD72110045 AD72210045 AD72310045 AD72510045 AD72610045 AD72710045 AD72810045 AD73010045
AD71415045 AD71515045 AD71615045 AD71715045 AD71815045 AD71915045 AD72015045 AD72115045 AD72215045 AD72415045 AD72515045 AD72615045 AD72715045 AD72815045 AD73015045
AD71410090 AD71510090 AD71610090 AD71710090 AD71810090 AD71910090 AD72010090 AD72110090 AD72210090 AD72310090 AD72510090 AD72610090 AD72710090 AD72810090 AD73010090 AD73205090 AD73205090
AD71415090 AD71515090 AD71615090 AD71715090 AD71815090 AD71915090 AD72015090 AD72110090 AD72215090 AD72315090 AD72515090 AD72615090 AD72715090 AD72815090 AD73015090
Green
Dk. Brown
Pink
Purple Blue Orange
Red Beige Clear White
Lavender Yellow
n/a n/a
n/a n/a
n/a n/a
n/a n/a
Lime
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
DISPENSING COMPONENTS ADL100 USER GUIDE
Barrel and Piston Kits (50) Barrels with (50) Pistons
Clear Barrels White Pistons
Clear Barrels
Amber Barrels
Amber Barrels
Black Barrels
Black Barrels Red Flat Pistons
Red Flat Pistons White Pistons
Red Flat Pistons White Pistons
3cc 5cc
903-NW 905-NW 910-NW 930-NW 955-NW
903-NWR 905-NWR 910-NWR 930-NWR 955-NWR
903-DW 905-DW 910-DW 930-DW 955-DW
903-DWR 905-DWR 910-DWR 930-DWR 955-DWR
903-BW 905-BW 910-BW 930-BW 955-BW
903-BWR 905-BWR 910-BWR 930-BWR 955-BWR
10cc 30cc 55cc
Tip Caps and End Caps (50) Pieces per pack Orange Blue
Clear
3cc End Cap 5cc End Cap 10cc End Cap 30/55cc End Cap Tip Cap Straight Tip Cap Round
AD903-ECO AD905-ECO AD910-ECO AD930-ECO
AD903-ECB AD905-ECB AD910-ECB AD930-ECB
n/a n/a
AD910-ECC AD930-ECC
Orange
Blue
Clear
Black
White
Green
AD900-ORTC AD700-BLPK AD800-ORTC AD900-BTC
AD900-CLTC AD900-BLTC AD900-WHTC AD900-BLACK n/a
AD7015LLW
n/a
AD900-GN
Adapter Assemblies Supplied Each Black Head Black Head
Yellow Head 3 ft clear hose
Yellow Head 6ft clear hose
Yellow Head
Black Head
3 ft clear hose
6ft clear hose
Only
Only
AD70303BHB AD70306BHB AD70303RHB AD70303RHB AD703R AD70503BHB AD70506BHB AD70503RHB AD70506RHB AD705R AD71003BHB AD71006BHB AD71003RHB AD71006RHB AD710R AD73003BHB AD73006RHB AD73003RHB AD73006RHB AD730R
AD703RB AD705RB AD710RB AD730RB
3cc 5cc
10cc
30/55cc
Big Barrel and Piston Kits (10) Barrels with (10) Pistons includes air cap and air hose Clear Barrels Amber Barrels Black Barrels White Pistons White Pistons White Pistons 100cc AD100L-N AD100L-A AD100L-B 200cc AD200L-N AD200L-A AD200L-B 300cc AD300L-N AD300L-A AD300L-B 400cc AD400L-N AD400L-A AD400L-B 500cc AD500L-N AD500L-A AD500L-B
Bench Stands - Premium Stand (Left), Budget Stand (Right) Premium Stand Budget Stand For Barrels For Barrels 560021 STD0140
Allows for hands free dispensing on a work bench.
Finger Switches - Plastic Body (Left), Velcro Version (Right)
Plastid Body Finger Switch
Velcro Wrap Around Finger Switch
AD9012 AD9065 The ADL100 is supplied with both electric foot switch and electric Velcro finger switch. These are spare part options.
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
WARRANTY ADL100 USER GUIDE
ADL One Year Limited Warranty All the specified components of Adhesive Dispensing Ltd dispensers are warranted to the original end user for one year from date of purchase. Within the period of this warranty, Adhesive Dispensing Ltd will repair or replace free of charge any defective component on return of the part, or the complete dispenser, prepaid to the Warehouse. In no such event shall any liability or obligation of Adhesive Dispensing Ltd arising from this warranty exceed the purchase price of the equipment. Before using, the user shall determine the suitability of the product for their intended use, and the user assumes and accepts all risk and any liability whatsoever in connection therewith.
This warranty is valid only when clean, dry and filtered air is used on the equipment.
Adhesive Dispensing Ltd makes no warranty whatsoever of merchantability or fitness for a particular purpose. In no event shall Adhesive Dispensing Ltd be liable for incidental or consequential damages.
ALWAYS SWITCH OFF THE DISPENSER WHEN NOT IN USE TO CONSERVE POWER. ALWAYS WEAR SAFETY GLASSES AND GLOVES WHEN IN USE. USE FUME EXTRACTION FOR ADHESIVES THAT EMIT EXCESSIVE OR DANGEROUS ODOURS.
Adhesive Dispensing Ltd 14 Clarke Road Mount Farm, Milton Keynes, MK1 1LG, UK
Tel. +44 (0) 1908 686660 Fax. +44 (0) 1908 686836
UK Freephone. 0800 094 9058 UK Lo-call Phone. 0845 652 0058 www.adhesivedispensing.co.uk email: info@adhesivedispensing.co.uk
©2025 Adhesive Dispensing Ltd ADL100MAN_5
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
Precision Fluid Dispenser ADL100 USER GUIDE
Serial Number: _________________________________________________________________________ Date Purchased: _______________________________________________________________________ Notes: ________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
Reasons to use our dispensing components Industrial grade - certified safe for use to 100 psi. Will not break when in use under pneumatic or mechanical pressure. Certified Silicone-Free . Our components will not contaminate fluids placed when in use including specialist adhesives. Burr-free . All blunt tips are electro-polished and produced to a high precision finish. Widest range - we stock millions of parts in many different styles and an extensive range of cartridges, nozzles, mixers. Fast lead times . Most products are held in stock and available within days not weeks. Boxed - most of our tips are supplied in sealed boxes for easy identification and protection against contamination. Batch codes - all labelled with batch codes for traceability. Expert support . We recommend our products to ensure our customers receive the right solution for their application.
Visit our growing customer tech knowledge base for more product information, data sheets, videos and advice. https://www.adhesivedispensing.net/kb_results.asp
Adhesive Dispensing Ltd 14 Clarke Road Bletchley, Milton Keynes Buckinghamshire, MK1 1LG, UK Tel. +44 (0) 1908 686660 Fax. +44 (0) 1908 686836 info@adhesivedispensers.co.uk https://www.adhesivedispensing.co.uk
© 2025 Adhesive Dispensing Ltd
www.adhesivedispensing.co.uk info@adhesivedispensers.co.uk +44 (0) 1908 686660
Made with FlippingBook Digital Publishing Software