900-25-USERGUIDE

Setup Continued

Assemble Fluid Reservoir:

Locate the reservoir pressure chamber and remove the cap (5) by turning counter clockwise.

Insert a 2.5oz size cartridge reservoir that is pre-filled with your assembly fluid, in the retainer (7) . Remove the storage cap from the large end of the cartridge.

Re-attach the reservoir chamber cap by aligning the slots in the cap with the slide bolts (8) on the chamber pushing down and turning clockwise until tight.

Slide the assembled reservoir chamber into the reservoir holder (16). Centre the pres- sure vessel so the weight is evenly balanced in the holder and tighten the thumb screw (9) to secure.

Assemble 90 Degree Elbow:

Remove the end cap from the polyethylene cartridge reservoir.

Locate the cartridge adapter (10) and thread it into the polyethylene cartridge reser- voir by turning clockwise.

Locate the 90-degree elbow (11) and thread it into the cartridge adapter by turning clockwise. Make sure the open end of the adapter is pointed up when finished.

Assemble Air In Line:

Locate the pressure regulator (15) and air in hose (12). Connect the air pressure regulator to your air source.

Connect the opposite end of the air input hose (13) to a pneumatic dispenser such as the TS924 footvalve, TS250 dispenser or TS350 dispenser.

Connect the opposite end of the air input line to the air pressure regulator by insert- ing the twist lock adapter and turning clockwise. This is also a filter and will ensure the air supply is clean and dry. ote: Be certain your plant air is properly filtered and dry. Please use the 5 micron filter part # TSD800-6FR, to guarantee dry filtered air. A regulated and constant air pressure must be supplied to the reservoir filler.

6